If this is your first visit, be sure to check out the FAQ by clicking the link above. You may have to register before you can post: click the register link above to proceed. To start viewing messages, select the forum that you want to visit from the selection below. |
|
|
Thread Tools | Display Modes |
#1
|
|||
|
|||
Installing three zone controller on your kiln
Dear fellow potters,
I just purchased and installed a three zone controller for my kiln. I would like to warn anyone who is considering doing this. I am generally satisfied with the controller itself, and the company provided me with responsive and competent technical support. But they did not guide me in determining whther my kiln would be sufficiently powerful enough, and I am disappointerd with this. So here is my advise. There is one major thing that you must consider before retrofitting a 3-zone controller to your kiln. Your kiln must have considerable surplus power to reach your highest working cone. And I do mean considerable. Here's why. When you run your kiln manually, and let's say your reach your cone in the last half hour at a rate of 108 DegF\Hr. Then, assuming that you are running at full capacity to achieve this, then you will certainly not be able to maintain this same rate with the kiln controller. The controller will be switching your elements on and off as it tries to maintain even heat, so only a percentage of your kiln's capacity will be used. Consequently, it will not be able to maintain your intended rate of heating and may not even be able to reach your cone. I am not an expert, so I can't give you any kind of formula to use for determining this. However, it would seem that if you can reach your cone reasonably by running at, say, only two-thirds of your full power (such as running with only 4 elemnts out of 6 total), then it might work out okay. If not, you'll still be able to run your kiln unattended, but you will not be able to get uniformly heated zones at the end of your fire. |
Thread Tools | |
Display Modes | |
|
|
Similar Threads | ||||
Thread | Thread Starter | Forum | Replies | Last Post |
Retrofitting your kiln with a 3-zone digital controller | Davis Salks | Pottery | 0 | December 24th 06 11:42 PM |
Important - Please beware of a company called Bohle | Eric Russell | Glass | 2 | August 23rd 04 07:46 PM |
FAQ Raku part 2 of 2 | SBRANFPOTS | Pottery | 0 | October 21st 03 02:13 PM |
FAQ Raku part 2 of 2 | SBRANFPOTS | Pottery | 0 | September 16th 03 11:11 PM |
Raku FAQs | Tom Buck | Pottery | 0 | July 20th 03 04:49 AM |